multi conductor spec sheet banner

AWG  20
Conductor Stranding  7/28
Nom. Insulation Thickness 2 Conductor @ 0.016
3 Conductor @ 0.016
4 Conductor @ 0.016
6 Conductor @ 0.016
8 Conductor @ 0.016
10 Conductor @ 0.016
15 Conductor @ 0.016 
Nom. Jacket Thickness  2 Conductor @ 0.032
3 Conductor @ 0.032
4 Conductor @ 0.032
6 Conductor @ 0.032
8 Conductor @ 0.032
10 Conductor @ 0.032
15 Conductor @ 0.032
Nom. O.D. 

2 Conductor @ 0.207
3 Conductor @ 0.217
4 Conductor @ 0.236
6 Conductor @ 0.276
8 Conductor @ 0.297
10 Conductor @ 0.345
15 Conductor @ 0.393

 


Shielded multiconductor 20 AWG cables are used for a multitude of purposes; things like consumer electronics and industrial process control equipment. They are used in advanced signal transmissions in controlled environments as well. This means that multiconductor cables are used for controlling equipment. By using 20 AWG shielded multiconductor cable, you are given the option of selecting between 2 to 15 conductors.

Why would you use shielded multiconductor 20 AWG cable? In many industrial facilities and other similar environments, there is a lot going on. What I mean by that is that there is a lot of equipment with a lot of wires running through a given facility. This can lead to EMI (electromagnetic interference) also called RFI (radio frequency interference). EMI/RFI can seriously reduce the performance of a circuit. In some cases, it can stop the circuit from functioning at all. This is where you would want to use shielded multiconductor 20 AWG cable. The shielding in this cable works in two ways. For starters, the shield can reflect energy. This prevents that energy from interrupting the circuit. Next, the shielding can help to conduct the rest of that energy to the ground. These actions make sure that the EMI/RFI does not reach the conductors.

These cables meet the requirements for UL, CSA, and NEC. Temperatures and voltages may not be the exact same from cable to cable. Call a Pacer expert for specifications on multiconductor cable.

Features:

  • 100% Flexfoil aluminum/polyester foil facing out
  • Stranded tinned copper drain wire
  • Fully annealed stranded tinned copper per ASTM B-33
  • Premium grade color coded PVC insulation
  • Grey PVC jacket

Compliances:

  • Coast Guard, NMMA, & ABYC Standards
  • NEC Article 800 Type CM (UL: 75°C)
  • UL Style 2464 ( UL: 80°C, 300 V, VW-1 )
  • CSA CMG (CSA: 60°C)
  • CE: Low Voltage Directive (LVD 2006/95/EC)
  • RoHS compliant directive 2011/65/EC
  • Vertical tray cable flame test per UL1581 and IEEE 383 (70,000 BTU)

Applications:

  • Consumer electronics
  • Industrial process control equipment
  • Suitable for EIA RS-232 applications
  • Advanced signal transmission in controlled environments